1. Overview & Statutory Accounting Principles
Under ISO 14064-1:2018 Clause 5.2 and the GHG Protocol Corporate Accounting and Reporting Standard, regulated facilities must maintain complete, verifiable activity records for all Scope 1 (Direct Fuel & Process Combustion) and Scope 2 (Purchased Electricity & Steam) emission streams.
Carbonatoz enforces deterministic activity data ingestion with continuous unit validation, automatic IPCC/DEFRA statutory emission factor resolution, and cryptographic SHA-256 evidence anchoring.
2. Standard Emission Source Classification Matrix
Ensure activity data is categorized under the proper source stream before recording:
| Scope | Stream Category | Common Industrial Fuel / Source | Standard Statutory Unit | Statutory Calculation Method |
|---|---|---|---|---|
| Scope 1 | Stationary Combustion | Natural Gas, Heavy Fuel Oil, Coking Coal, Diesel (DG Sets) | Nm^3, Metric Tonnes, Litres | Emission = Activity × NCV × EF_{fuel} × OF |
| Scope 1 | Mobile Combustion | Forklifts, Plant Yard Trucks, Heavy Earthmovers | Litres, Gallons | Emission = Fuel\ Consumed × EF_{mobile} |
| Scope 1 | Industrial Process | Lime Calcination, Sinter Decarbonization, Anode Consumption | Metric Tonnes (Raw Material) | Emission = Feedstock × Stoichiometric\ Factor |
| Scope 2 | Purchased Electricity | State Grid Utility Supply, Dedicated Captive PPA | kWh, MWh | Emission = Consumption × Grid\ Factor\ (CEA/IEA) |
| Scope 2 | Purchased Steam / Heat | District Heating, Cogeneration Import | GJ, MWh_{th} | Emission = Imported\ Enthalpy × Boiler\ Efficiency\ Factor |
3. Step-by-Step Procedure: Manual Activity Ingestion
Follow these operational steps to input and lock monthly activity data:
452500.00).Utility Invoiced, Continuous Meter (SCADA), or Manual Tank Dip Measurement.pending_approval status in the facility queue. Once approved by the Facility Manager or Lead Accountant, the record is locked permanently.4. Technical Note: Factor Precedence & Automated Validation
5. Error Diagnostics & Remediation
| Validation Issue | Description | Root Cause & Resolution |
|---|---|---|
| Inactive Source Stream | Source Stream Inactive | The selected equipment stream has been marked as decommissioned or in maintenance. Update stream status in FacilitiesSource Register. |
| Duplicate Invoice Reference | Duplicate Invoice Reference | An activity record with this exact invoice reference number has already been recorded for this facility. Check the existing ledger before re-entering. |
| Out-of-Bounds NCV Value | NCV Value Exceeds Standard Limits | The entered custom NCV deviates by more than 20% from IPCC standard benchmark ranges. Verify laboratory test units (MJ/kg vs GJ/t). |